Mace DVR1604RW DVR User Manual


 
 
  !
35
IP is set by using  or input the exact numbers to change
the IP address. IP address setting can only be here. The related
SUBNETMASK and GATEWAY should be set according to the IP
address. MONITOR and PLAYBACK can be changed by using
TCP/IP or MULTICAST. Save the setting in SAVE, and restart the
recorder.
Note:
MULTICAST: The users with Admin levels can monitor each channel
freely. All other users can only view after Admin
releases camera. 5 users at maximum.
TCP Protocol: All users are able to monitor any channel. User shall
select Camera # desired. If the transmission is over
Internet, TCP should be chosen. 2 users can log in at a
maximum.
Select the Camera channel in CH. Open or close (On/Off)
the function in STATE. Choose how long you want to
continue the recording (10, 20, 30, ……90SEC) when motion is detected
and then cleared. ALMOUT controls the alarming state for motion
detection. SENS has three levels: LOW, MID, HIGH. AREA can be
accessed by pressing ENTER. The setting area can be divided in 192
sections. Red section means the current cursor position, and the blue
section is the motion detection area. Areas with no color are no motion
detection areas. Press Fn to locate the current section, then move the
cursor to cover the MD area needed; press Fn again to choose the MD
area. Press  to get the setting and press ENTER to confirm.
Network

CH 1
DELAY 30 SEC
ALMOUT OFF
SENS MID
AREA SET
SLOT1 08:00AM – 08-00PM ON
SLOT2 08:00AM – 08-00PM OFF
SAVE CAMCE;
Motion detection








