Mitsubishi Electronics AJ61QBT11 Home Theater Server User Manual


 
12 - 6
MELSEC-QnA
12 COMMUNICATION IN THE COMPOUND SYSTEM
X0040 X004F
PLS M302
M302
SET M303
M303
Refresh instruction
When the data link
startup is completed
normally by the
parameters in the
buffer memory
SM402
SET Y40
SET Y46
X0046
RST Y46
RST M303
When the data link
startup is completed
fault by the parameters
in the buffer memory
X0047
RST Y46
RST M303
D100 K1FROM H0004 H0668
Data link by the
parameters in the
buffer memory
X0040 X004F
PLS M304
M304
SET M305
M305
When registration
parameter to E
is completed normally
2
PROM
SET Y4A
X004A
RST Y4A
RST M305
X004B
RST Y4A
RST M305
D101
K1
FROM H0004 H06B9
Registering
parameters
to E
2
PROM
Register
command
When registration
parameter to E
is completed fault
2
PROM
: Refer to Section 8.2 when usin
g
the software version E
(
manufactured in Au
g
., 2001
)
or later of the A1SJ61QBT11.