Omega RD2800 DVD Recorder User Manual


 
-34-
7. PROGRAMMING
7.3 List of Programming Items
1 Parameters to be Programmed First
Parameters Key operations
Programming
items
Defaults Programming ranges
Ref.
page
Range No. 07
01 to 10, 21 to 56, 70 to 80
RJ enable/
disable
0
0 (disable), 1 (enable: thermocouple range only)
Range/
printing
range
*
+
Printing
range
0.000 to 5.000
Max. 10 digits (minimum value to maximum
value). Excluding decimal point.
8.2
°C/°F
calculation
+
(3 sec. or more)
°C
°C (°C calculation) °F (°F calculation)
Thermocouple and resistance thermometer
range only
8.3
Chart speed +
20/25 *
0001 to 0600 mm/h or 0001 to 0200 mm/min.
8.4
* RD200: 20 mm/h, RD2800: 25 mm/h
2 Other Programmable Parameters and Functions
Parameters Key operations
Programming
items
Defaults Programming ranges
Ref.
page
Clock +
Japanese
time
2000.01.01.00:00 to 2099.12.31.23:59
11.1
Scale * +
0.000 to 5.000
Max. 11 digits (minimum value to maximum value),
excluding decimal point. Printing range reflects to the
scale. Therefore no programming is normally
necessary for thermocouple and resistance
thermometer range.
11.2
Skip * +
Not
programmed
Programming is required in [Range/Printing range]
programming mode.
Channel to be deleted Clear the range/printing
range.
Channel to be recovered Program the range/
printing range.
11.3
Subtract
printing *
+
Not
programmed
Programming is required in [Range/Printing range]
programming mode.
[Subtract printing CH] = [Reference CH] – [subtraction CH*]
* Can be replaced with [reference value (with decimal
point)].
11.4
CH/output
type
Not
programmed
Select from CH (1 to 4), Fail* or C.End (chart end).
* Recorders with alarm output (option) only.
Level
Not
programmed
Up to 4 alarm points can be programmed to each
channel (CH 1 to 4).
Alarm
types
H
Applicable to CH (1 to 4) selected in CH/output type
mode.
H/L (absolute value high/low limits)
E/F (absolute value high/low limits with standby)
U/d (rate-of-change increase/decrease limits)
b/S (differential high/low limits)
J/k (differential high/low limits with standby)
Relay No. 0
Applicable to recorders with alarm output (option)
Relay No. "0" to "n" can be programmed. ("0": no
output), n: number of output points.
For recorders without alarm output (option), the
number is fixed as “0”.
Alarm
values
Not
programmed
Max. 5 digits including (-) sign.
Sign is not necessary when U/d, b/S or J/k is selected.
Measuring
count
Not
programmed
1 to 20, Programming required only when U/d is
selected.
Alarm
Ref. CH
Not
programmed
1 to 4, Programming required only when b/S and J/k
are selected.
11.5
* Programming is required to each channel. For 1-pen type, programming is only for CH 1. The items without *
mark are programming common to all channels. For "alarm", programming is required to each level of
channels.
SHIFT
7
RANGE
SHIFT
1
CHART
SHIFT
SHIFT
SHIFT
SHIFT
SHIFT
4
SCALE
7
RANGE
7
RANGE
8
ALARM
CLOCK
SHIFT