55
Time code/user bit
Setting the external time code
1
Set the VTR to stop mode.
3
Set the TCG switch to EXT. (External time code
selection)
4
The following settings can be selected with setup
menu No. 505 (EXT TC SEL).
LTC:
The LTC signal input to the TIME CODE IN
connector (XLR) on the rear panel is recorded
as TC.
<Note>
LTC must be synchronized with the video signal.
VITC:
The VITC of the input video signal is recorded
as TC.
2
Select “TC” using the COUNTER button.
Reproducing the time code/user bit
1
Set the VTR to stop mode.
3
Press the PLAY button.
Playback starts and the time code is shown on the
display.
When the SUPER switch is set to ON, the time
code value is superimposed on the video signals
from the VIDEO OUT 3 connector.
<Notes>
O By installing the SDI board (AJ-YA755G, available
as an optional accessory) in the VTR, the time code
value is also superimposed onto the video signals
which are output from the SDI OUT 3 connector.
O When the time code signal cannot be read, the time
code is automatically interpolated by the CTL
signal.
The display appears as shown below.
2
Select “TC” or “UB” using the COUNTER button.
T 2 R 00:01:04:072
When the time code
signal cannot be read,
an asterix (2) is
displayed.
“ ”: 1, 3 field
“2”: 2, 4 field
The colon between the seconds and
frames changes to a period during
drop frame mode.