13
Front panel
UAUDIO MON SEL (L and R) buttons
These buttons are used to select the audio signals
which are to be output to the MONITOR L and R
connectors.
Each time the L button is pressed, the signal to be
output to the MONITOR L connector is changed in
the following sequence: CH1 5 CH2 5 CH3 5
CH4 5 CUE.
Similarly, each time the R button is pressed, the
signal to be output to the MONITOR R connector is
changed in the following sequence: CH1 5 CH2 5
CH3 5 CH4 5 CUE.
Which signal has now been selected is displayed by
the lighting of the L or R lamps on the level meter
display.
When AUTO has been selected as the setup menu
No. 721 (MONI CH SEL) setting, the display is
switched in tandem with the monitor output. The
channel to which monitor output is to be switched
automatically can be selected using setup menu No.
735 (MON AUTO SEL).
VAUDIO MON SEL (MIX) button
This button is used to select the mixed signals which
are to be output to the MONITOR L and R
connectors.
Each time the AUDIO MON SEL (L) button is
pressed while this button is held down, the signals
to be output to the MONITOR L connector change in
the following sequence: CH1 + CH2 5 CH3 + CH4
5 CH1 + CH3 5 CH2 + CH4 5 mixing release.
The mixed signals to be output to the MONITOR R
connector are changed in the same way by the
AUDIO MON SEL (R) button.
WAudio level control knobs
These knobs are used to adjust the recording and
playback level of the PCM audio signals (CH1, CH2,
CH3 and CH4).
Whether the recording level or the playback level is
to be adjusted is selected using the AUDIO VOL
SEL (REC/PB) switch X.
Parts and their functions
(continued)
XAUDIO VOL SEL (REC/PB) switch
This switches the function of the audio level control
knobs W between recording and playback.
REC:
Adjustment of recording level
PB:
Adjustment of playback level
YAUDIO VOL SEL (UNITY/VAR) switch
UNITY:
At this position, the audio signals are recorded or
played back at a fixed level regardless of the
positions of the audio level control knobs W.
VAR:
At this position, the audio signals are recorded or
played back at the level adjusted by the audio
level control knobs W.
<Note>
It is not possible to set it so that both the recording
level and playback level can be adjusted.
When REC LEVEL is selected, UNITY (fixed level)
is set for the playback level; when PB LEVEL is
selected, UNITY is set for the recording level.
ZSET button
When this button is pressed, the data which has
been set using the setup menus is entered.
After the data has been entered, the setup menu
settings are exited, and the original status is
restored.
When the internal time code has been set, the data
which has been set is entered.
[DIAG button
When this button is pressed, the VTR information is
displayed.
When it is pressed again, the original display is
restored.
The VTR information consists of the “WARNING”
information, “HOURS METER” information and
“UMID” information.
Switching between the display of each type of
information is accomplished by pressing the search
button.
Displayed on the “WARNING” screen are details of
the warnings.
Displayed on the “HOURS METER” screen are the
deck’s serial number, power-on time, drum rotation
time, tape travel time, number of times a cassette
has been loaded, number of times the power has
been turned on and off, and so on.
Displayed on the “UMID INFO” screen are details of
the UMID (Unique Material Identifier) information.
ON
POWER
REMOTE
SUPER
REC INH
TCG
MODE
ON
OFF
DVCPRO 50
EJECT
SEARCH
TC
CUE
VIDEO
ASSEM
COUNTER
CH 1 CH 2 CH 3 CH 4
PF 1 PF 2 PF 3 PF 4
RESET
PLAYER
RECORDER
SET
TC PRESET
MENU
PF
STAND BY
EDIT
A OUT
OUTIN SET
A IN
PREROLL
AUTO EDIT
PREVIEW/
REVIEW
INPUT SELECTMETER
AUDIO MON SELAUDIO MIXHEADPHONES
AUDIO VOL SEL
VIDEO
CH 1
ENC
VIDEO
LEVEL
CONTROL
REMOTE
PRESET
MANUAL
LOCAL
RMIX
1&2
CH1/3
PULL
CH2/4
REC CH1/3
CH1/3CH2/4
REC CH2/4
3&4
L
CH 2 CH 3 CH 4
AUDIO
FULL/FINE
RECPLAY
REW FF
SHIFT
PULL
STOP
INSERT
PUSH
DVCPRO
DV
2
X
OFF
REC
PB
UNITY
VAR
ON
OFF
INT
EXT
TAP E
EE
XL/L/M-
cassette
SHTL
JOG
SLOW
CHROMA
LEVEL
PRESET
MANUAL
SET UP
BLK
PRESET
MANUAL
PRESET
REGEN
PRESET
REC RUN
FREE RUN
MANUAL
HUE
TC
DIAG
CHROMA PH
V Z
YX W
U
[