Panasonic AJ-D850P VCR User Manual


 
– 89 –
Displaying the “HOURS METER” information
Turn the search dial to move the cursor ( ). The description for the item where the cursor is located is shown on
the counter display.
Item No. Item Description
H00 OPERATION
H01 DRUM RUN
H02 TAPE RUN
H03 THREADING
H11 DRUM RUN r
H12 TAPE RUN r
H13 THREADING r
H30 POWER ON
<Notes>
• The resettable items in the “HOURS METER” information are reset by the shop when performing maintenance or
other work.
The search buttons and the search dial cannot be operated while the DIAG menu is displayed.
If “T&S&M” is selected in the setup menu No. 003 (DISPLAY SEL), a message appears in the mode display
whenever a warning or error occurs. When multiple events occur, the event with the highest priority is displayed.
Priority Display Description
High Error messages
(See error message table)
INT SG
NO INPUT
Warning messages
(See error message table)
Low
Warning messages
Priority Monitor display Description VTR operation
High FAN STOP Operation continues
SERVO NOT LOCKED
Operation continues
LOW RF
Operation continues
HIGH ERROR RATE
Operation continues
OVER RECORDING
Operation continues
Low
Displays the time that the power has been supplied in one-hour units.
Displays the time that the drum has been rotating in one-hour units.
Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,
VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in
one-hour units.
The number of times for threading/unthreading is displayed in single units.
Displays the time that the drum has been rotating in one-hour units. (Can be reset)
Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,
VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in
one-hour units. (Can be reset)
The number of times for threading/unthreading is displayed in single units. (Can be reset)
This displays the number of times the power has been turned on in 1-time increments.
When an abnormal operation is detected in this unit, the AUTO OFF lamp lights up
and an error message is displayed.
If “BB” in No. 601 (INT BB SIG) in the setup menu is selected or when ON has been
selected as the setup menu No. 722 (INT SG) setting, pressing the REC button or
the EDIT button (E to E mode) will display “INT SG” for the first two seconds. This is
also displayed for the first two seconds when starting editing.
If there is no input signal (except for analog audio) to the connector selected using
the INPUT SELECT switch, pressing the REC button or the EDIT button (E to E
mode) will display “NO INPUT” for the first two seconds. This is also displayed for
the first two seconds when starting editing.
When a warning occurs in this unit, the warning lamp lights up and a warning
message is displayed. When multiple warnings occur, the warning with the highest
priority is displayed.
This is displayed when the fan motor stops.
This is displayed when the servo is not locked for three or
more seconds during playback, recording, or editing.
This is displayed when envelope levels approximately 1/3
that of normal levels are detected for more than one second
during playback, recording, or editing.
This is displayed when the error rate increases and
correction/interpolation is performed on either the video or
audio playback signal.
When voice-over editing is performed using the internal
audio memory, this message appears if the duration of the
signals recorded in the memory exceeds 20 seconds.