– 13 –
<Front Panel Center Section>
$6 Volume control
This is used to adjust the headphones volume and the monitor output volume.
Whether the headphones output and monitor output volumes are to be linked or kept
separate can be set on the setup menu No. 708 (MONI OUT). (Note that the headphones
output volume is normally linked.)
When the volumes are kept separate, the monitor output is set to the unity value (preset
value).
$7 MONITOR SELECT switches
These are used to select the audio signals output to the monitor L/R channels.
Each time the “L” button is pressed, the signals output to the monitor L channel are
selected in turn in the following order: CH1, CH2, CUE and back to CH1.
Each time the “R” button is pressed, the signals output to the monitor R channel are
selected in turn in the following order: CH1, CH2, CUE and back to CH1.
The L or R lamp on the level meter display lights to indicate which signal is now being
selected. (When the unit is set to “AUTO 1” or “AUTO 2” in No. 713 (MONI CH SEL) on the
setup menu, then the display will change according to the monitor output.)
$8 METER (FULL/FINE) selector switch
This switch is used to select the scale unit display mode for the audio level meters.
FULL mode: Standard scale units (ranging from –∞ to 0 dB) are used.
FINE mode: The scale is divided up into 0.5 dB increments.