Philips FPF42C128135UA-52 CRT Television User Manual


 
Service Modes, Error Codes, and Fault Finding
EN 10 FHP PDP5.
5. Service Modes, Error Codes, and Fault Finding
Index of this chapter:
5.1 Repair Tools
5.3 Process Flow
5.4 Repair Instructions
5.5 Defect Description Form
5.1 Repair Tools
To be able to repair the Plasma Display Panels on board level,
the following repair tools are available:
Special LVDS cable: T.B.D.
Foam buffers: 3122 785 90581.
Figure 5-1 Extension cable kit ALiS PDP
Figure 5-2 Foam buffers for FTV
5.2 Error codes
When an error causes the PDP to switch “OFF”, an error code
is put into an EEPROM on the Logic Board. You can read out
the contents of the error code memory with the ComPair tool.
5.2.1 How to Connect the ComPair Tool
Carefully disconnect the LVDS cable from CN01 on the
Logic Board.
If necessary connect a PSU with a voltage of 3.3V to drive
the LOGIC board.
Connect the cable from the ComPair tool to connector
CN01 of the LOGIC board.
Turn on the ComPair tool.
Launch the ComPair software.
Read out the error buffer.
5.2.2 Error Code Overview
Table 5-1 Error code table
G_16400_018.eps
270706
Power Supply
Logic Board
CN06
CN01
I
2
C
Compair
Vpr
3
SDA
GND
SCL
CN06
I
2
C
Compair
8
6
4
CN01
3k3
3k3
14
E_14580_024.eps
250304
Error code Detected by board Error description Suspected board(s)
21 X-SUS Vxx power voltage is too high X-SUS LOGIC
24 Vxx power voltage is too low X-SUS LOGIC
25 Vex power voltage is too high X-SUS
26 Vex power startup is faulty X-SUS LOGIC
44 Y-SUS Vey power voltage is too low Y-SUS LOGIC
45 Vey power voltage is too high Y-SUS
46 Vey power startup is faulty Y-SUS LOGIC
4C Temperature too high Y-SUS LOGIC
61 X-SUS
Y-SUS
Vs power voltage is too high Y-SUS X-SUS LOGIC PSU
62 Vs power startup is faulty X-SUS Y-SUS PSU LOGIC
64 Ve power voltage is too low LOGIC X-SUS Y-SUS
65 Ve power voltage is too high Y-SUS Y-SUS
66 Ve power startup is faulty LOGIC X-SUS Y-SUS
68 Vw power voltage is too low Y-SUS LOGIC
69 Vw power voltage is too high LOGIC Y-SUS
6A Vw power startup is faulty Y-SUS LOGIC
79 Vw power current is too high (during operation) Y-SUS X-SUS LOGIC
7B Vs power voltage is too high (during startup) Y-SUS X-SUS LOGIC