Runco VX-2ix Projection Television User Manual


 
VX-2ix Color Gamut Adjustment
Runco VX-2ix Owner’s Operating Manual A-3
Figure A-3. VX-2ix Secondary RS-232 Port
4. Connect the color sensor to any available COM or USB port.
5. Launch HyperTerminal. Open a connection using these parameters: 19200 baud,
8
data bits, no parity,1 stop bit and no flow control.
6. Press <Enter>. The VX-2ix responds with “+>” to indicate that it is ready to accept
commands.
7. Start your color analyzer. Position the sensor approximately 6 to 12 inches from the
screen, facing it at a slight angle (upward or to one side) so that the color of the
screen is included in the calibration.
A.3
Serial Command
Syntax
Table A-1 lists the serial command set for color gamut adjustments. The “Parameter
(min/max)” column shows the valid parameter ranges, or “NA” for commands that take no
parameters.
When you enter a valid command, the VX-2ix executes it and acknowledges it with a plus
sign on the command line (+ >). When you enter an invalid command – one that is
misspelled or followed by values outside the valid range for that command – the VX-2ix
ignores it and returns a minus sign (- >).
Table A-1. Serial Commands for Gamut Adjustment
Command
Parameter
(min/max)
Value
Stored?
Description
GAMUT WHITE NA NA
Displays white field on screen for
measuring x and y coordinates;
shows current x and y
coordinates for white on the
command line.
GAMUT RED NA NA
Displays red field on screen for
measuring x and y coordinates;
shows current x and y
coordinates for red on the
command line.