Runco VX-33I Projection Television User Manual


 
34 Runco VX-33i Installation/Operation Manual
PRE
L
IMINAR
Y
Connecting 12-volt
Trigger Outputs to
External Equipment
If your VX-33i is equipped with a CineWide with AutoScope system, connect the
AutoScope lens motor to a 12-volt trigger output on the VX-33i; see Figure 3-16.
Similarly connect other 12-volt trigger-activated equipment (such as retractable screens or
screen masks) to the other trigger outputs.
For more information on using the 12-volt triggers, refer to Triggers on page 58.
Figure 3-16. 12-volt Trigger Output Connections
Rear Panel
HD1 (RCA)
HD1 (RCA)
AutoScope Lens Motor (Rear)
Tip = +12V
Sleeve = Ground
3.5-mm
mini plug
AC Input
Power
Switch
Retractable Screen or other
12-volt trigger-activated
device