Speco Technologies 4TL DVR User Manual


 
TL H.264 DVR User’s Manual
75
5.6.5 Alert Notification Setup
This function allows users to send alert notifications to the CMS program
which had been installed to users’ computer. For detailed setup instruction,
please refer to the CMS user’s manual.
Alert Notification Setup
1. Alert Configuration Set
2. Alert Notification
3. Alert IP
4. Alert Port
5. Alive Interval
1
OFF
0.0.0.0
9999
120 Sec
5.6.5.1 Alert Configuration Set
<Alert Configuration Set> provides 3 combinations of Alert Notification, IP,
and Port.
5.6.5.2 Alert Notification
Four options are included in this item; <OFF>, <Event>, <Alive>, and <Both>.
<OFF>: The Alert Notification is turned off.
<Event>: When the alarm is triggered, the DVR will send an alert message to
the CMS.
<Alive>: The DVR will send an alive message to the CMS every N second
just to show you that the connection between the DVR and CMS is
in effect. The time interval N can be adjusted in <Alive Interval>.
<Both>: This enables the DVR to send both Event and Alive alert messages
to the CMS.
5.6.5.3 Alert IP
The Alert IP must match the IP address of the computer.
5.6.5.4 Alert Port
The ports for DVR and the CMS Alert MUST be the same.
5.6.5.5 Alive Interval
Users can define the time interval (1 to 255 seconds) between each alive
message.