8. Technical data
Tuner
input frequency: 950-2050 MHz
input resistance: 75 ohms
input level: 44-78 dBV
input connection: F connector
bandwidth: 27 MHz
tuning: PLL frequency synthesis
Outdoor unit supply
LNB supply voltage: 14 V / 18 V switchable at a maximum of 400 mA
modulation with 22.2 kHz,Vp-p = 500 mV
can be switched off
feed only in active mode, switchable to
permanent feed using an internal coding jumper,
also in standby mode
polarizer current: -60 mA... + 60 mA adjustable in steps of
approx. 2 mA
Video
deemphasis
PAL: CCIR REC 405-1
MAC: according to MAC specification
output level: Vp-p = 1 V
output: SCART & CINCH connector
output resistance: 75 ohms
Decoder output
mode of operation: 4 different signals switchable
output level: Vp-p = 1 V or 0.4 V (flat)
output: SCART & CINCH connector
output resistance: 75 ohms
Audio
carrier frequency (PAL): 5.5 ... 8.7 MHz
IF bandwidth (PAL): 130/200/280/380 kHz switchable
modes of operation (PAL): mono/stereo switchable
deemphasis (PAL): 50 Ês, 75 Ês, J 17, adaptive
(Panda-Wegener compatible)
50 Hz... 15 kHz
output level: Vp-p = approx. 2 V in case of full drive
output: SCART & CINCH connector (left, right)
HF modulator
UHF range: channel 32...42 adjustable
preset to channel 39
colour standard: PAL G
UHF output level: 74 +/- 4 dBÊV
UHF output: IEC male connecto
antenna input IEC female connector