Wegener Communications 4422 DVR User Manual


 
Page 54
UTY4422-002 Page 54 of 72
P O R T : n R A T E : d d . d d d
P R O G : p p p p p
(This is identical to the Home Screen)
PORT: n is the ASI input port,
RATE: yyyyy.yy is the input data rate,
PROG: zzzzzz is the program number (5 digits).
If tracking mode is entered while viewing the following screen, the display will jump to MODE
& DURATION screen under TRACKING.
A S I I N P U T E R R O R :
x x x x x x x x x x x x x x x
ERROR: xx…xx is a message describing the ASI Input Card Error. The error messages are:
Message Meaning
NO SIGNAL
The ASI Input card is not seeing the sync byte every 188 bytes.
Make sure the ASI input cable is connected.
FIFO EMPTY
The ASI Input FIFO is underflowing. This could mean the data
rate is set too high. Ensure that the incoming data rate equals the
unit’s data rate.
FIFO FULL
The ASI Input FIFO is overflowing. This could mean the data rate
is set too low. Ensure that the incoming data rate equals the unit’s
data rate.
FIFO SYNC ERROR
The FIFO detected a sync error from the FIFO. Check the data rate
settings.
The following screen is shown only if applicable (values non-zero).
N O M P E G : n n n A T T E M P T S
B A D H D R : m m m A T T E M P T S
NO MPEG: nnn is the number of times the unit timed out in GET MPEG sub-mode, and the
ASI Input Card was still locked (if non-zero).
BAD HEADER: mmm is the number of times the unit has seen an invalid header in GET
COMPEL sub-mode (if non-zero).
R E T U R N
P r e s s < S E L E C T >
Moves to second level screen, “Settings Status.”