Xantrex Technology RC7 Universal Remote User Manual


 
Configuring the RC/GS and RC7
975-0210-01-01 17
Set Clock (RC/GS Only)
Some RC/GS automatic generator start functions are based
on the time of day. The clock must be properly set to ensure
the programmed function will perform at the correct time.
The clock uses 24-hour time and ranges from 00:00 to 23:59.
To access the Set Clk menu, scroll down past the generator
menus by pressing the down arrow. A flashing cursor appears
below (and behind) the hour (H) or minute (M) characters in
the screen. Every eight seconds the cursor alternates
positions. When the cursor is under the hour digit, press the
Settings button to set the hours to the current hour (00 to 23).
When the cursor is under the minutes digit, press the Settings
button to set the minutes to the current minute (0 to 59). Press
and hold the Settings button to quickly increase the selected
value, or press and release to increase the value by one unit at
a time.
Select Genset (RC/GS Only)
After setting the clock, press the up arrow once to access the
Select Genset menu. Select the type and model of the
generator by pressing the Settings button until the generator’s
name and model is displayed. The default is Onan
QuietDiesel.
Figure 3-9
LCD Contrast menu items
Figure 3-10
Set Clock display
LCD Contrast:
Max Contrast
LCD Contrast:
87%
LCD Contrast:
62%
LCD Contrast:
Min Contrast
Set Clk: 0-23:59
HH:MM
Hour selected
Increase value (Settings button)