System Status Displays
975-0210-01-01 41
Meters Display
The RC/GS and RC7 have built-in meters that monitor
inverter/charger activities. To view these meters, press and
hold the Meter Mode button (up arrow) for five seconds until
the screen clears. Use the down arrow button to scroll
through the meter displays. The information contained in
these displays can be useful for troubleshooting the system.
Average Shunt Amps
This meter displays the averaged current flowing through the
internal shunt to and from the batteries. The inverter/charger
must be wired correctly for the internal shunt to work (see the
RV Series Inverter/Charger Owner’s Manual for more
information). If more than one inverter/charger is used, an
external shunt connected in the main line between the battery
negative and the green inverter chassis ground terminal is
required.
Battery Voltage
This meter displays the current battery voltage level. Use this
meter to check the condition of the batteries or monitor the
levels under load.
Figure 4-18
Meter Mode Button
Meter Mode
Menu Item
Setup
Meter Mode button
Avg Shunt Amps:
+/- 0 Amps DC
Battery:
00.0 Volts DC
RC-GS_manual.book Page 41 Friday, May 20, 2005 4:57 PM