4-6
To remove a Power Control board:
1. a) Unplug cooktop or disconnect
power.
b) Remove the cooktop from
installation.
c) Remove cooktop glass.
d) Remove the aluminum plate.
e) Disconnect the wires from the power
control board terminals.
f) Remove 2 screws.
g) Slide the board from under the two tabs
on the interior side of the board and lift
the power control board from its holder,
see gure 1. (left board shown).
To remove the EMI (Filter) Board:
1. a) Unplug cooktop or disconnect power.
b) Remove the cooktop from installation.
c) Remove cooktop glass.
d) Remove the elements.
e) Remove the aluminum plate.
f) Disconnect the wires from the EMI (lter)
board terminals, see gure 1.
g) Remove 5 screws.
h) Lift the EMI (lter) board from its holder,
see gure 3
.
To replace the fuses on the Filter (EMI)
board:
1. a) Unplug cooktop or disconnect
power.
b) Remove the cooktop from installation.
c) Remove cooktop glass.
d)
e) Remove the aluminum plate.
f) Remove and replace fuses as
needed, see gure 2.
Removing, Power Control Board, Fuses and EMI Board
Screws
Figure 1
Figure 2
Figure 3
Fuses
Tabs
Screws
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Remove the elements.
Power Control Board
EMI (Filter Board)
Disconnect Wires