A SERVICE OF

logo

6-5
Troubleshooting (continued)
F-36, F37 Temperature sensor is not working Type 1 1. Disconnect power.
2. Check that the temperature sensor is between 184,000 -
292,000
at room temperature and is rmly plugged in. If the
sensor is not between 184,000 - 292,000 Ω, replace the coil
and go to Step 5. If the sensor is between 184,000 - 292,000
and the electrical connection is good, go to Step 3.
3. Replace all parts and panels before operating.
4. Reconnect power and check that the coil is wor
king. If it is not
working, disconnect power and replace the non-working coil and
the control board.
5. Replace all parts and panels before operating.
6. Reconnect power.
7. If the control was replaced in Step 4, recongure the cooktop
following the directions in “Manual Conguration Mode.”
F-40 Power control board failure Type 1 or Type 2 1. Disconnect power.
2. Check that the cable between the User Interface and the power
control board is good and prop
erly connected. If the cable needs
repair, x it.
3. Replace all parts and panels before operating.
4. Reconnect power.
5. Verify if error is still present. If yes, disconnect power.
6. Replace the power control board.
7. Replace all parts and panels before operating.
8. Reconnect power.
9. Recongure the cooktop following the directions in “Manual
Conguration Mode.”
F-42 2 epyTylppus rewoP 1. Check for 240 volts AC at the main incoming power
supply
connection by
completing the following steps.
2. Disconnect power.
3. Connect voltage measurement equipment.
4. Reconnect power and check for 240 volts at J1 L to N, and then
J2 L to N at the EMI lter board, and then J1 L to N at both power
control boards. If voltage is correct, disconnect power, replace
the power control board and go to Step 5. If voltage is not
correct, disconnect power and check for an open fuse on the EMI
lter board.
If there is not an open fuse, have a qualied
electrician check the home power supply.
5. Replace all parts and panels before operating
6. Reconnect power.
7. Recongure the cooktop following the directions in “Manual
Conguration Mode.”
F-47 Power supply from power control
board to User Interface is missing
or WIDE communication error
between UI and power control
board or an open fuse on the lter
board
Type 2 1. Disconnect power.
2.
Check
that the cables between the User Interface and the power
control board are not damaged and are rmly plugged in.
3. Replace all parts and panels before operating.
4. Reconnect power and check that it is working. If it is not working,
disconnect power and replace the cables between the User
Interface and the power control board.
5. Replace all parts and panels before operating.
6. Reconnect power and check that it is working. If it is not workin
g,
go
to Step 7.
7. Disconnect power.
8. Check the continuity between black luge at the terminal block
and both L2 terminals on the EMI board. If there is not continuity
on one or both of these lines, replace the thermofuse harness.
9. Replace all parts and panels before operating.
10. Reconnect power and check that it is working. If it is not working,
go to Step 11.
11. Disconnect power.
12. Check the continuity of the fuses on the EMI board. If ei
ther
of the
fuses is blown, replace with a new one.
13. Replace all parts and panels before operating.
14. Reconnect power and check that it is working. If it is not working,
go to Step 15.
15. Disconnect power.
16. Change both control boards.
17. Replace all parts and panels before operating.
18. Reconnect power and recongure the cooktop following the
directions in “Manual Conguration Mode.” Check that it is
working. If it is not working, go to Step 1
9.
19
. Disconnect power.
20. Change the User Interface.
21. Replace all parts and panels before operating.
22. Reconnect power and recongure the cooktop following the
directions in “Manual Conguration Mode.”
Service Code
Shown on Display
Failure Description Type of Failure Repair Suggestions