Black Box A/S-4 TV Converter Box User Manual


 
CHAPTER 13: Troubleshooting Problems and Odd Installation Problems
75
PROBLEM SYMPTOM POSSIBLE REMEDIES
TCTS light is on and a. Baud rate of A/S-4
TTX light does blink does not match terminal
when power is applied baud rate. Check baud
to the A/S-4 rate switches, refer
to Section 4.1.
b. Switches SW3/1,2,3 and
4 are not set correctly,, refer to
Section 4.1 and 4.2.
3. Power up message a. Baud rate of A/S-4
has some incorrect does not match terminal
letters or just baud rate. Check baud
garbage letters rate switches, refer
displayed to Section 4.1.
b. Parity and word length
of A/S-4 and terminal
do not match. Check
option switches, refer
to Section 4.5.
4. Receive power up TCD light on front of a. A/S-4 switches SW2,
message on terminal the A/S-4 is off SW3 and SW6 for terminal
but typing home or port not set correctly,
space bar will not refer to Section 4 in
display main menu manual.
b. Terminal device does
not supply DTR (if modem
device is hooked to
terminal port, it does
not supply DSR). Turn
on SW6/4 so A/S-4
unit will supply DTR.
(If modem device turn
on SW6/5 so A/S-4
unit will supply DSR).
TCD light is on, on the a. Switches SW3/1,2,3 and
front of the A/S-4 4 are not set correctly,
and the TRX light does refer to Section 4.1
not flash when a key is and 4.2.
typed on the terminal.
TCD light is on on the a. Switches SW2/8 and
front of the A/S-4 SW6/1, 2 and 3 are
and the TRX light does set incorrectly, refer
flash when a key is to Section 4.1 and 4.2.
typed on the terminal.