6.7.4 Network setup
Figure 6.36 The Network setup window
TCP/IP settings
The [DHCP], [IP address], [Subnet mask], [Gateway], [Primary DNS], [Secondary DNS] and [Remote
client port no.] option settings are not available in the client program. You can set these options in
the system menu of the DVR.
HTTP port no.: Enter the HTTP port number.
Bandwidth limit: Enter the bandwidth to adjust the data traffi c.
Mail settings
Set the mail options.
• Notifi cation: When you mark up the notifi cation option, notify the user about unit operating
information by e-mail according to your notifi cation settings.
TLS: Mark up when using the TLS (Transport Layer Security) function.
SMTP server: Enter the SMTP server address.
SMTP port no.: Enter the SMTP port number. Typically the TCP port used for SMTP is 25.
However, in some cases it is better to change this port number for added fl exibility or security.
If desired, change the port number (1 ~ 65535).
User name: Enter the user name.
Password: Enter the password.
Mail address (1~3): Enter the mail address. You can input up to 3 e-mail addresses.
Note:
The [SMTP server], [SMTP port no.], [User name] or [Password] settings
are optional. The DVR can send e-mail directly without the use of an SMTP
server or an MTA (message transfer agent). In certain cases all e-mail
should be forwarded to a specific SMTP server. Specify the server host
name or IP address in such cases. For more detail on SMTP setup, ask your
network administrator and/or mail service provider.
Notification
Set the notifi cation options.
Alarm on: Sends an e-mail when an input has been activated.