INSPECT AND TEST THE UNIT BEFORE INSTALLING
Inspect The Unit
1. Carefully inspect the Plasma Display Electric Pop-Up Lift
(PUL) for shipping damage. If any damage is apparent, call
your carrier claims agent and do not continue with the installa-
tion until the carrier has reviewed the damage.
NOTE: Read all assembly instructions before starting assem-
bly.
2. Carefully inspect PUL components for damage, checking verti-
cal extrusion arms to make sure they are parallel.
IMPORTANT: Before mounting the lift in the furniture/cabinet,
make the following tests to be sure that it operates properly and has
not been damaged in shipping.
Test The Unit
1. Set the PUL on a clean, level surface.
2. Connect the motor control box to the control circuit housing
(see Figure 1, Figure 2, and Figure 3).
3. Install two terminal blocks in control box (see Figure 2).
NOTE: The lift is supplied with a momentary push button on
the end of a cable to help you pretest the operation.
3. Connect the momentary push button (provided) cable leads to
terminals #6 and #1 and add a jumper wire (provided - electri-
cal wire about 4 in. long with 1/4 in. stripped at each end)
between terminals #2 and #5 on the same terminal block (see
Fig. 4).
4. Plug the lift’s power cord (see Figure 3) into a 110V 60 Hz or
220V 50 Hz (as appropriate) 15-amp outlet.
NOTE: The lift draws approximately 1.5 amps.
WARNNG: Be aware during the
installation that this is a motorized
device, and there are pinch points for
people and for electrical wiring.
Keep hands and electrical wiring
away from internal components of
the mechanism
5. Operate the lift much like a garage-door opener: press the but-
ton when the lift is at its “bottom” position and it will move
“up”; press again when it is at its “top” position and it will
move “down”; press while moving and it will stop.
Use the push button to check that the lift runs to the top and
bottom of its travel without any interference that might indicate
damage during shipment.
6. Unplug the lift’s power cord.
To
To push button
To jumper
Figure 1. Connection to Housing
Figure 2. Front Connection to Control Box
Figure 3. Back Connection and Power Cord
Figure 4. Test Wiring
to Control Box