46 About Your System
Plug & Play
Configuration
Error
Error encountered in
initializing PCIe device;
faulty system board.
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards."
Quad rank DIMM
detected after
single rank or
dual rank DIMM in
socket.
Invalid memory
configuration.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines."
Read fault
Requested sector
not found
The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.
Replace the optical medium,
USB medium or device.
Ensure that the SAS
backplane, USB, or SATA
cables are properly
connected. See
"Troubleshooting a USB
Device," "Troubleshooting an
Optical Drive," or
"Troubleshooting a Hard
Drive" for the appropriate
drive(s) installed in your
system.
SATA Port
x
device
not found
There is no device connected
to the specified SATA port.
Information only.
Table 1-2. System Messages (continued)
Message Causes Corrective Actions