EDR910_1610_ma_en_rev1 00 - 45 -
3.10 RS232/RS485 MENU
Define the settings for DVR remote control through serial interface in the RS232/RS485
menu. Pin assignment and remote control protocol are described in appendix B and C.
(1) RS232 BAUD RATE: RS-232 interface transmission speed. 1200, 2400, 4800,
9600, 19200 and 3840 baud can be selected.
Default setting: 9600 baud
(2) RS232 STOP BIT: Number of stop bits: 1 or 2
(3) RS232 PARITY: Parity mode: NONE / EVEN / ODD
(4) RS232 DATA BIT: Number of data bits: 8 or 7
(5) RS485 BAUD RATE: RS-485 interface transmission speed. 1200, 2400, 4800,
9600, 19200 and 3840 baud can be selected.
Default setting: 9600 baud
(6) RS485 STOP BIT: Number of stop bits: 1 or 2
(7) RS485 PARITY: Parity mode: NONE / EVEN / ODD
(8) RS485 DATA BIT: Number of data bits: 8 or 7
(9) RS232/RS485 ID: RS232/RS485 address. Addressable range: 1~255.
This address complies with the device number for remote
control through keyboards EKB 500, KS KBK and KS KBJ
(DEVICE No.).
(10) PTZ-PROTOCOL: Protocol type setting for network telemetry control,
available protocols:
EVERFOCUS1 (EPTZ1800 Dome),
EVERFOCUS2 (EPTZ1000/3000 Dome),
ED2200/2250 (complies with Samsung protocol
SCC-641/643),
Pelco-D, Pelco-P
NOTE: Standard setting for EKB500 keyboard connection:
RS-485 Baud Rate: 9600, 1 stop bit, Parity NONE, RS232/RS485 ID = Device/DVR
Nr. at keyboard
CONTROL SETUP MENU
RS232
BAUD RATE 9600 BPS
STOP BIT 1
PARITY NONE
DATA BIT 8
RS485
BAUD RATE 9600 BPS
STOP BIT 1
PARITY NONE
DATA BIT 8
RS232/RS485 ID 1
PTZ PROTOCOL EVERFOCUS