Sybase 11.9.x-12.5 Home Theater Server User Manual


 
Server Error Messages 12200 - 12299
1180
Server Error Messages 12200 - 12299
Number Severity Text and Explanation
12201 20 Lock found in lock cache not on global lock chain: dbid %d, objid %d, locktype %d,
sufficiency class %d
Explanation: Adaptive Server encountered an internal error affecting the current
process. Reconnect to Adaptive Server. Report the error to your System Administrator so
dbcc diagnostics can be run.
12202 10 Could not initiate lock wait checking because Adaptive Server has run out of alarms. If
your application uses this feature, try rebooting the server.
Explanation: This is an informational message. Unless otherwise specified, no action is
required. Contact your System Administrator about any warning issued in the message.
12203 18 Lock cache entry not found for spid %d, lock 0x%lx, type %d, suff class %d. Please notify
your system administrator.
Explanation: Command failed due to internal Adaptive Server problem. Perform any
diagnostic action indicated by the message. Report the error to your System
Administrator.
12204 18 Attempted to redo deadlock search as a result of a lock upgrade. Found too many
SH_NKL lockrecs. Please contact Sybase Technical Support.
Explanation: Command failed due to internal Adaptive Server problem. Perform any
diagnostic action indicated by the message. Report the error to your System
Administrator.
12205 17 Could not acquire a lock within the specified wait period. %s level wait period=%d
seconds, spid=%d, lock type=%s, dbid=%d, objid=%ld, pageno=%ld, rowno=%ld.
Aborting the transaction.
Explanation: Command failed due to resource limitation. Modify the command to fit
available resources, retry when the resource is available, or contact your System
Administrator to address the resource problem.
12206 20 Internal Error in lock manager routine: Attempted lock anti-inheritance when the parents
sdes chain does not include the dbid and objid corresponding to the child thread which are
dbid=%d and objid=%d.
Explanation: Adaptive Server encountered an internal error affecting the current
process. Reconnect to Adaptive Server. Report the error to your System Administrator so
dbcc diagnostics can be run.
12207 10 Could not acquire a lock within the specified wait period. %s level wait period=%d
seconds, spid=%d, lock type=%s, dbid=%d, objid=%ld, pageno=%ld, rowno=%ld.
Explanation: This is an informational message. Unless otherwise specified, no action is
required. Contact your System Administrator about any warning issued in the message.