MKP 2000 Remote Control Panel • Installation
MKP 2000 Remote Control Panel • Installation
Installation, cont’d
2-6
7a. If you are using a mud ring, follow the directions, if any,
that came with the mud ring to attach the clips that fasten
the ring to the wall or furniture (figure 2-3).
To meet the UL listing requirements, this device must be
installed in a wall box.
M
K
P
2
0
0
0
4
5
6
1
2
3
7
89
B
A
C
K
0
C
A
N
C
E
L
I
N
P
U
TO
U
T
P
U
T
T
A
K
E
R
Detail A
0.75" #6-32 Screw
Backing Clip
Backing Clip
Sheet Rock
Sheet Rock
Mounting Bracket
Mounting Bracket
Detail B
1.25" #6-32 Screw
Backing Clip can
be in either orientation.
See Detail A or Detail B.
Extron
MKP 2000
Figure 2-3 — Attaching a mud ring to a wall
7b. If you are using a wall box, insert the wall box into the
opening, and attach it to the wall stud/furniture with nails
or screws, leaving the front edge flush with the outer wall
or furniture surface (figure 2-4).
If attaching the wall box to wood, use four #8 or #10
screws or 10-penny nails. A minimum of 1/2 inch (1.3 cm)
of screw threads must penetrate the wood.
If attaching the wall box to metal studs or furniture, use
four #8 or #10 self-tapping sheet metal screws or machine
bolts with matching nuts.
Flush with
Wall Surface
Screws or Nails
Wall Stud
Wall Box
Figure 2-4 — Attaching a wall box to a wall stud
8. Connect the Ethernet and/or RS-232 cable (as appropriate)
and the power cable and test the MKP before fastening the
MKP into the wall box. See Rear Panel and Side Panel
Connections on page 2-8, for details.
The rear panel connectors will be inaccessible after
installation.
Mounting the MKP to the mud ring or wall box
1. Remove power from the control panel by disconnecting
the power supply.
2. Place the control panel through the opening in the wall or
furniture and into the wall box. Take care not to damage
the cables, which fit behind the MKP, at the back of the
wall box.
2-7