SETTING FOR RS-485 USE
The RS-485 interface can be used to operate the VCR
using a SANYO brand system controller.
NOTE:
œ Refer to the instruction manual for the system
controller.
Setting the Address, Data Transfer
Speed and Termination
œ Make this setting without a cassette tape inserted.
1
Press the PLAY button for 3 seconds or more.
ø Ad and the address number appear on the
digital display.
2
Press the l (or j) button to set the VCR address
(from 000 to 127).
ø The address set appears on the digital display.
3
Press the ENTER button.
4
Press the l (or j) button to set the data transfer
speed (19200, 2400, 4800, 9600).
ø The data transfer speed set appears on the
digital display.
5 When finished, press the PLAY button.
6
Move the shorting bar of the RS-485 interface board
to change the TERMINATION setting.
ON (Terminated) OFF (Not terminated)
NOTE:
œ When the MENU RESET button is pressed, the
setting appearing on the digital display is reset to the
default setting.
Settings when using RS-485
1 Press the MENU button to display the MAIN MENU.
2 Press the l (or j) button to select the 8.OTHERS
line, then press the ENTER button.
ø The (OTHERS) menu appears.
<OTHERS>
*ALARM@LOG
*POWER@FAILURE/DEW
*RS-485@SET
@@STATUS@INFO.@@@Y
@@ALARM@INFO.@@@@Y
3
Press the l (or j) button until the STATUS INFO.
setting is highlighted, then press the ENTER button.
4
Press the l (or j) button to set the STATUS
INFO.” setting, then press the ENTER button.
Y. . . . . . . . . . The VCR status information is
output at the RS-485 connector.
N. . . . . . . . . . The status information is not
output at the RS-485 connector.
5
Press the l (or j) button until the ALARM INFO.
setting is highlighted, then press the ENTER button.
6
Press the l (or j) button to set the ALARM INFO.
setting, then press the ENTER button.
Y. . . . . . . . . . The VCR alarm information (alarm
recording start and stop) and
video loss information are output
at the RS-485 connector.
N. . . . . . . . . . The VCR alarm information (alarm
recording start and stop) and
video loss information are not
output at the RS-485 connector.
7
Press the MENU EXIT button.
NOTE:
œ When a warning state (non-recording or mechanical
problem) occurs, the warning state is output from the
RS-485 connector. However, non-recording warning
states are not output if NON REC is set to “N” in the
(WARNING OUT/EJECT SET) menu.