Intel SC5400 Home Theater Server User Manual


 
Intel® Server Chassis SC5400 User’s Guide 57
9. Insert new power distribution board into power supply cage (see letter “A” in the
following figure). Try to route the power cables to the appropriate area at the time
of insertion (see Steps 9 and 10 below). Position the power distribution board on the
four standoffs inside the power supply cage. Push down on the power distribution
board to securely attach it to the standoffs (see letter “B”). Tighten thumb screw
(see letter “C”).
Note: Cables on back of power distribution board not shown to clarify insertion process.
Figure 61. Securing Power Distribution Board to Power Supply Cage
10. Connect the P1, P14, and P16 cables to the server board. See the Intel
®
server
board Quick Start User’s Guide or User Guide for appropriate connection
locations.
11. Reconnect power cables to other chassis components as appropriate.
A
C
B
TP00693