Matrix Audio 12X Flat Panel Television User Manual


 
Manual # 26-0301000-00 / Revision C MatrixPRO 12x - 12 Input Matrix Switcher 33
Description: Lock / unlock the front panel from user input. Locking the front panel will result in the front panel not
responding to user button presses.
Parameters: en - [0|1], Disable|Enable
Query:
FPLOCK?
Returns the current front panel lock status in the format:
=en
Example: FPLOCK 1 (Locks the front panel from the user.)
Command:
GCLEAR grp
Description: Clears the selected grouping information.
Parameters: grp - Group number to clear; [1-8]
Example: GCLEAR 1 (Clears the grouping information in group number 1.)
Command:
GADD grp out in
Description: Add output and/or input to the selected group index. Note: cannot add output to more
than 1 group index.
Parameters: grp - Group number to add output/input; [1-8]
out - Output number to add; [1-8] / 101 if no output to add
in - Input number to add; [1-12] / 101 if no input to add
Example: GADD 1 4 2 (Add output 4 and input 2 to group 1.)
GADD 1 101 5 (Add input 5 to group 1)
Command:
GDEL grp out in
Description: Remove output and/or input from the selected group index.
Parameters: grp - Group number to remove output/input; [1-8]
out - Output number to remove; [1-8] / 101 if no output to remove
in - Input number to remove; [1-12] / 101 if no input to remove
Example: GDEL 1 4 2 (Remove output 4 and input 2 from group 1.)
GDEL 1 101 5 (Remove input 5 from group 1)
Command:
IPCONFIG I3 I2 I1 I0
Description: Sets the MatrixPRO’s IP address
Parameters: I3 - First set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
I2 - Second set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
I1 - Third set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
I0 - Fourth set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
Query:
IPCONFIG?
Returns the current IP address the MatrixPRO is set to in the format:
=I3.I2.I1.I0
Example: IPCONFIG 192 168 0 141 (Set MatrixPRO IP address to 192.168.0.141)
Command:
LOADRMP
Description: Places unit into loader mode. This mode is used to perform field upgrades
Parameters: None.
Example: LOADRMP (Puts unit into loader mode.)
Command:
OMUTE out mte
Description: Updates output mute status