Matrix Audio 12X Flat Panel Television User Manual


 
Manual # 26-0301000-00 / Revision C MatrixPRO 12x - 12 Input Matrix Switcher 35
Query:
RTEMP? out
Returns the current video and audio inputs routed to the specified output in the format:
=in audio
Example: RTEMP 1 3 4 (Route to output 1, video input 3, audio input 4.)
RTEMP 4 101 5 (Route to output 4, audio input 5)
Command:
SBAUD mode
Description: Serial Baud Rate. Selects between 19.2, 28.8, 38.4, or 57.6K baud.
Parameters: mode - Mode; [0|1|2|3], 19200|28800|38400|57600
Query:
SBAUD?
Returns the current serial baud in the format.
=mode
Example: SMODE 0 (Sets Serial baud rate to 19200.)
Command:
SMODE mode [485id]
Description: Serial Mode. Selects between RS-232 or RS-485 serial modes. If select RS-485 mode, also need
to specify RS-485 ID.
Parameters: mode - Mode; [0|1], RS-232|RS-485
485id - RS-485 ID for the MatrixPRO. This field is ignored if switching to RS-232 mode
Query:
SMODE?
Returns the current serial mode in the format.
=mode 485id
Example: SMODE 0 (Sets Serial mode for RS-232.)
SMODE 1 10 (Sets Serial mode for RS-485 with ID 10)
Command:
SWITCH mode
Description: Video switching mode. Selects either RGB delay, Vertical Sync, Composite Sync, or V Ref Sync.
Parameters: mode - Mode; [0|1|2|3], RGB|Vsync|Comp|VREF
Query:
SWITCH?
Returns the current video switching mode in the format.
=mode
Example: SWITCH 0 (Sets video switching mode to RGB delay.)
Command:
TAKE en
Description: Route / Cancel all pending video/audio routes.
Parameters: en - Mode; [0|1], Cancel all pending|Route all pending. 0 is the equivalent of pressing the
ESC button on the front panel. 1 is the equivalent of pressing the TAKE button on the front panel.
Example: TAKE 1 (Routes all pending video/audio routes.)
Command:
UNOV
Description: Saves the system parameters to non-volatile RAM. The system parameters
stored are the current output/input routes, grouping information, IP setting and serial port
configuration parameters. Upon power up, the system parameters stored in non-volatile RAM are
used for system configuration.
Parameters: None
Example: UNOV (System parameters are saved to non-volatile RAM.)