NEC MT1030+ Projection Television User Manual


 
47
This section helps you resolve problems you may encounter while setting up or using your MultiSync MT830+/MT1030+/MT1035+ LCD Projector.
Status Light Messages
TROUBLESHOOTING5
TROUBLE SHOOTING
91
92
Status
Normal
The projector lamp has exceeded 2000 hours of operation and
should be replaced.
Either the lamp cover or filter cover is not fastened properly. Check
each and reattach them if necessary.
The cooling fan has stopped. Contact your NEC dealer for service.
The lamp is not turned on.
The projector was turned off and back on too quickly. Turn
off the projector, wait one minute, then turn the projector
back on. Or the lamp is burnt out.
Condition
OFF
On continually
Blinking very rapidly
(On and off in a cycle of 1 sec.)
Blinking slowly
(On and off in a cycle of 8 sec.)
Blinking very slowly
(On and off in a cycle of 12 sec.)