I NTELLIP AD
®
Ci TOUCH S CREEN K EYPAD
23
Figure 12
TS-1 mounting heights and optimal viewing angles for people of different heights.
I NTELLIP AD
®
Ci TOUCH S CREEN K EYPAD
22
INSTALLATION CONSIDERATIONS
Where to Mount a TS-1 Keypad (continued)
Avoid installing the TS-1 Touch Screen Keypad in the following areas, which can degrade oper-
ation or accessibility:
• In direct sunlight or strong ultraviolet light
• Over heat-generating or moist areas
• Behind an opened door
•Next to a thermostat (since the TS-1 generates heat that can affect thermostat settings)
CAUTION: Do not install the TS-1 into electrical boxes with 110-volt devices.
Some states or municipalities allow devices such as the TS-1 Keypad to be installed into the same
electrical box with 110-volt devices, provided a “low-voltage partition” is used between the
devices.
We do not recommend this action. If you must locate a TS-1 Keypad near electrical devices, install
it in a separate metal electrical box, ground the box to the electrical system ground, and route the
speaker wires several feet away from the electrical wiring.
Recommended Mounting Height
The TS-1 Keypad is designed with a viewing angle of 42°, as shown in Figure 12 on the next page.
NOTE: The recommended mounting height depends on the user’s height and distance from the TS-1.
Before mounting, determine the average height of all users to find a mounting height that will
work best. As an example, for a 6' person standing about 2' away, mount the TS-1 at 60" above
the floor (see Figure 12). For a 5' person, use a mounting height of 48".