Servo reference setting tables
The servo reference signal is switched as shown in the tables below depending on the servo
reference setting, deck mode and what input signal is available. When the mode is
transferred to editing or recording/playback, the image may be disturbed and the transfer
may be delayed if the references during playback and recording do not match.
During playback or special playback
SERVO REF
Input signal status
on the setup menu
Reference signal
No. 304 position
VIDEO IN signal
REF IN signal
(servo reference)
REF IN signal
AUTO
EXIT
Internal sync signal
REF IN signal
Internal sync signal
REF IN signal
Internal sync signal
REF IN signal
Internal sync signal
During recording or editing
SERVO REF
Input signal status
on the setup menu
Reference signal
No. 304 position
VIDEO IN signal REF IN signal
(servo reference)
VIDEO IN signal
VIDEO IN signal
AUTO
EXIT
REF IN signal
Internal sync signal
REF IN signal
Internal sync signal
REF IN signal
Internal sync signal
"
denotes that the signal is not supplied.
"
"
denotes that the signal is supplied:
"
When BBor CBis set for the setup menu No. 600 and internal signal generation has been
selected, the REF IN signal serves as the servo reference when the REF IN signal is
provided and the internal sync signal serves as the servo reference when the REF IN signal
is not provided.