Panasonic WV-CU161 Home Theater Server User Manual


 
10
Check the DIP switch settings before connecting this controller. They need to be changed only if you want to change the sys-
tem settings.
The following setting procedure should be made by qualified service personnel or system installers.
DIP Switch Setting
Caution: Unplug the AC cord before changing any DIP switch setting.
Removing the Bottom Cover for SW1
1. Take off the bottom cover by removing the two screws.
CONNECTIONS
SW1
SW1 lets you choose 0/5V or open collector (O.C.) for
the alarm recover output signal.
0/5V: +5 V DC approx. 500 m sec.
Open Collector (O.C.): 16 V DC 100 mA max.
The initial factory setting is 0/5V.
Remove two screws.
Bottom Cover
Panasonic
SW1
SW1
O.C 0/5V
NOR: White with Black border
REV: Black with White border
The initial factory setting is NOR.
SW4
Confirm that SW4 on the board is set as shown below.
This switch is used only for factory tests. Do not change
this switch setting.
SW100
SW100 lets you choose the mode for displaying charac-
ters on the monitor.
Bit
ON
OFF
1234
SW4
SW100
NOR REV
Removing the Bottom Panel for
SW100
1. Take off the side panels by removing the four screws.
2. Take off the bottom panel by removing the 8 screws.
SW100
Remove four screws.
Remove four screws.
q
w