adjust
RS-232C/LAN Information Timing
Set up the informing manner for no signal or temperature rising.
While RS-232C controls: Warning or error message sent on the display automatically.
While LAN controls: Acquire the warning or error message from the display.
RS-232C/LAN Information Timing
No Signal Warning Timing
No Signal Warning
No Signal Error
Temperature Warning
No Signal Error Timing
Temperature Warning Value
Temperature Warning Release Value
5min
On
On
On
10min
55°C
52°C
Press ACTION ( ) button
Options
2/3
Initial Power Mode
Off-timer function
ID select
Serial ID
Remote ID
Studio W/B
LAN Control Protocol
RS-232C/LAN Information Timing
Normal
Enable
0
Off
Off
Protocol 1
Off
No Signal Warning
If set to “On”, the display sends out the no signal warning.
No Signal Warning Timing
Set up the detecting time for no signal warning.
No Signal Error
If set to “On”, the display sends out the no signal error.
No Signal Error Timing
Set up the detecting time for no signal error.
The warning of “No Signal Warning” and the error of “No Signal Error” are not sent when the no signal state is
detected through any of the following functions:
No Signal power off: Enable, PC Power management, DVI-D Power management, HDMI1 Power management,
HDMI2 Power management (see page 32)
Setting Example
No Signal Warning Timing: 5 minutes
No Signal Error Timing: 10 minutes
PC Power management: On (30 seconds)
If there is no signal when PC IN is input, “PC Power management” is activated ¿ rst and the Display enters the standby
mode.
Note:
The “No Signal Error Timing” cannot be set shorter than “No Signal Warning Timing”.
Temperature Warning
If set to “On”, the display sends out the warning temperature.
Temperature Warning Value
Set up the detecting temperature for temperature warning.
Temperature Warning Release Value
Set up the temperature to release the temperature warning.