Pelco C673M (2/01) DVD VCR Combo User Manual


 
14 Pelco Manual C673M (2/01)
ALARM RECORDING CONNECTION
Figure 3. Alarm Recording Connection
You can confirm an alarm from a distance by connecting the ALM OUT terminal with an
existing alarm system panel or other peripherals, such as a buzzer. Connect the VCR and
other peripherals as shown in Figure 3.
CONNECTING FOR SERIES RECORDING
Figure 4. Connecting VCRs for Series Recording
Connect the VCRs as shown in Figure 4. Refer to the Series Recording section for
information about series recording methods 1 and 2.
CONNECTING FOR REMOTE RECORDING
Figure 5. Connecting for Remote Recording
Connect the VCR with a remote switch as shown in Figure 5.
00431
GNDALM
ALARM SWITCH
RST
IN
REC ALM
MOD
CLK
OUT
CALL
EXTERNAL ALARM LAMP
AND BUZZER
ALARM RESET SWITCH
00432
GNDALM RS
IN
REC ALM
MOD
CLK
OUT
CALL GNDALM RST
IN
REC ALM
MOD
CLK
OUT
CALL
*1: THIS CONNECTION IS NECESSARY IN
CASE OF
SERIES RECORDING 2
.
*1
1ST VCR 2ND VCR
00443
GNDALM
REMOTE SWITCH
RST
IN
REC ALM
MODE
CLK
OUT
CALL