Samsung PE40C Flat Panel Television User Manual


 
48
Preparations
1
1 Preparations
1.6.3 Control Codes
Viewing control state (Get control command)
Controlling (Set control command)
Command
Issued IDs can be displayed in hexadecimals. However, ID 0 must be displayed as 0xFF.
All communications take place in hexadecimals. The checksum is calculated by adding up all values
except the header. If a checksum adds up to be more than 2 digits as shown below
(11+FF+01+01=112), the first digit is removed.
Header Command
ID
Data length
Checksum
0xAA
Command
type
0
Header Command
ID
Data length Data
Checksum
0xAA
Command
type
1Value
No. Command type Command Value range
1 Power control 0x11 0~1
2 Volume control 0x12 0~100
3 Input source control 0x14 -
4 Screen mode control 0x18 -
5 Screen size control 0x19 0~255
6 PIP on/off control 0x3C 0~1
7 Auto adjustment control 0x3D 0
8 Video wall mode control 0x5C 0~1
9 Safety Lock 0x5D 0~1
10 Video Wall On 0x84 0~1
11 Video Wall User Control 0x89 -