Samsung SIR-S4120R Satellite TV System User Manual


 
V. Viewing the
VCR Menu
5
4-17
DIGITAL VIDEO RECORDER
7
Communication Setup
The following illustrates the intial setting of the COMMUNICATION SETUP menu.
BAUD RATE
Sets data transmission rate in RS-232C communication.
[4,800/9,600/19,200/38,400/115,200]
NETWORK ACCESS/IPADDRESS/GATEWAY/SUBNET MASK
If the system is connected to a LAN, it can be controlled from the remote surveillance pro-
gram installed on a remote PC. To connect to a LAN, set the NETWORK ACCESS to ON,
and configure the IPADDRESS, GATEWAY, SUBNET MASK, etc. to suit the user’s net-
work environment. Then, connect the LAN Cable to the LAN Cable connection terminal on
the back of the system and reboot the system. If at least one from the IPADDRESS,
GATEWAY, and SUBNET MASK is modified, the system must be rebooted to apply the
modified setting to the system.
NETWORK USER ID/NETWORK USER PWD
In order to access the system through a LAN from a remote surveillance program installed
on a remote PC, the user ID and password must be entered. At this time, the user ID and
password entered match the ones set in the NETWORK USER ID and NETWORK USER
PWD, you can connect to the system; otherwise, you cannot gain access. Both are 4-digit
numbers and the initial set values are 0000.
PAN/TILT TYPE (Remote Control of Camera)
You can control the Pan/Tilt/Zoom function of a camera with the remote monitoring
program installed in the remote PC through LAN. Then, you shall select the camera to be
controlled. But, this remote control shall be applied only to SEC SCC-641/SCC-643(N/P)
Cameras and SCC-421(N/P) Series Camera(C4201, C4203, C4301 and C4303) Camera
which use the SAMSUNG Protocol. You can select the camera to be controlled by the
remote monitoring program. Please refer to Remote Monitoring Program Use’s Manual for
the detailed explanation of the remote monitoring program. [SCC-641/SCC-421]
COMMUNICATION SETUP
BAUD RATE 115,200
NETWORK ACCESS ON
IP ADDRESS 0. 0. 0. 0
GATEWAY 0. 0. 0. 0
SUBNET MASK 0. 0. 0. 0
NETWORK USER ID ****
NETWORK USER PWD ****
PAN/TILT TYPE SCC-421
MOVE=[//
/
] SELECT=[ ] EXIT=[MENU]
Caution
Caution
After setting IP ADDRESS, GATEWAY and SUBNET MASK, exit the MENU. Then, a
message "DO YOU REBOOT SYSTEM?" will appear. If you want to use the changed
NETWORK information, select “YES” to reboot the system.