Sanyo DSR-3709 DVR User Manual


 
RECORD SET3
English 79
7 Set “ALARM INTERLEAVE”.
[Settings] ( indicates default setting)
* Recording pattern for “SW” and “ONLY”
8 Set “REC RATE” and “DURATION”.
The maximum number of recording alarms (shown in
parentheses) changes in accordance with the new
settings.
(Default setting for recording rate: 15 FPS)
(Default setting for duration: 20 SEC)
[Settings]
*1
Operates while an alarm is being triggered. (5 sec.
minimum)
9 Press the [EXIT/OSD] button.
The setting procedure is ended and the display returns to
the normal screen.
“ALARM” and the number of alarms appear in the
operation display area.
When an alarm occurs, the alarm display flashes.
z If a new alarm occurs during alarm recording, the alarm
count is incremented in the same way as if two alarms
had occurred. However, in cases where alarms occur
consecutively on the same channel, alarm retrigger
settings (JP.84) can be used to ensure that these are
counted as one alarm only.
z Settings cannot be made for “PRE-ALARM
RECORDING” when “ALARM RECORDING” is set to
“OFF”.
1 Turn the jog dial to select “PRE-ALARM
RECORDING”, and then turn the shuttle
dial clockwise.
“OFF” flashes.
Setting Description
ONLY
Video is recorded only from cameras with an alarm
occurring.
SW
Recording is switched between camera video includ-
ing an alarm and video from all connected cameras.
Item Setting Description
REC RATE 30 to 0.033 FPS Sets the recording rate.
DURATION
5 SEC, 10 SEC,
20 SEC, 40 SEC,
1 MIN, 2 MIN,
3 MIN, 4 MIN,
5 MIN, 10 MIN,
15 MIN, CC
*1
Sets the recording time per
alarm.
<ALARM REC MODE SET>
ALARM RECORDING : ENABLED
PICTURE QUALITY : ENHANCED
AUDIO RECORDING : ON
ALARM INTERLEAVE : ONLY
REC RATE: A 15FPS, DURATION: 20SEC
PRE-ALARM RECORDING : OFF
REC RATE: **** FPS, DURATION: ****
=> (01679 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
02 02 02 02 020201 03 04
02 02 02 02 0201 03 04 040405 06 07 08
Alternate recording of multiple items of alarm video
Recording until the alarm is cancelled
Alarm Alarm
Alarm Alarm is cancelled
SW
ONLY
<ALARM REC MODE SET>
ALARM RECORDING : ENABLED
PICTURE QUALITY : ENHANCED
AUDIO RECORDING : ON
ALARM INTERLEAVE : ONLY
REC RATE: A 15FPS, DURATION: 20SEC
PRE-ALARM RECORDING : OFF
REC RATE: **** FPS, DURATION: ****
=> (01679 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
Maximum number of
alarm recording
When alarm recording settings have been
completed
To set pre-alarm recording
EXIT/OSD
01-01-04 00:00:00 REC REPEAT EN A ALARM 0000
02
Number of alarm
Alarm display
<ALARM REC MODE SET>
ALARM RECORDING : ENABLED
PICTURE QUALITY : ENHANCED
AUDIO RECORDING : ON
ALARM INTERLEAVE : ONLY
REC RATE: A 15FPS, DURATION: 20SEC
PRE-ALARM RECORDING : OFF
REC RATE: **** FPS, DURATION: ****
=> (01679 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
e00_l8hbg_us_7.book Page 79 Thursday, November 25, 2004 1:44 PM