Sanyo SRC-850 VCR User Manual


 
OUTPUT TERMINALS
SW OUT Terminal
When recording, a pulse signal is output at the SW OUT
terminal.
This terminal is usually connected to the switch input (SW
IN) of devices like a camera switcher unit, or a quad
compressor.
SW OUT Terminal Output Setting
1 Press the MENU button until the (SET UP 3) menu is
displayed.
@@@@@@@<SET@UP@3>
öBUZZER
@@@ALARM@IN@@@@@@Y
@@@TAPE@END@@@@@@Y
@@@KEY@IN@@@@@@@@N
@@@WARNING@@@@@@@Y
öSW@OUT
@@@OUTPUT@@@@@@@@Y
@@@TIMING@@@@@@@@FIELD
@@@FIELD@@@@@@@@@01
2 Press the ] button, until the “OUTPUT” setting is
flashing.
3 Press the l (or j) button, to set the desired output
mode.
Y . . . . . . . . . . When recording, a pulse signal is
output.
N . . . . . . . . . . When recording, a pulse signal is
not output.
4 Press the ] button, until the “TIMING” setting is
flashing.
5 Press the l (or j) button, to set “FIELD” or “FRAME”.
FIELD. . . . . . . 1 pulse is output after each set
number of fields.
FRAME . . . . . 1 pulse is output after each set
number of frames.
6 Press the ] button, until the “FIELD” (or “FRAME”)
setting is flashing.
NOTE:
If “TIMING” is set to FRAME (see step 5),
“FRAME” will be indicated instead of “FIELD”.
7 Press the l (or j) button, to set the desired pulse
signal interval.
Available settings are:
FIELD. . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field
FRAME . . . . . 01, 02, 03, 04, 05, 10, 30 or 60
frame
8 Press the PAUSE/SEARCH button to save the
setting.
SERIES OUT/NON REC OUT terminal
setting
The output at the SERIES OUT/NON REC OUT terminal
can be set.
1 Press the MENU button until the (SET UP 2) menu is
displayed.
@@@@@@@<SET@UP@2>
öDISPLAY
@@@DATE@@@@@@@@@@Y
@@@TIME@@@@@@@@@@Y
@@@ALARM@COUNT@@@Y
öTAPE@IN@MODE@@@@STOP
öTAPE@END@MODE@@@REW
öOUTPUT@@@@@@@@@@SERIES
öSERIES@REC@IN@@@N
öEJECT@MODE@@@@@@EJECT1
öTHREAD@CHECK@@@@Y
2 Press the ] button, until the “OUTPUT” setting is
flashing.
3 Press the l (or j) button, to select the desired output
mode.
SERIES . . . . . If during series recording, the
counter reading reaches 7:57:00
or the tape reaches the end, a
LOW signal (0 V) is output. The
LOW (0 V) signal is output for
about 70 seconds after the end of
the tape is reached.
NON REC . . . If during recording the VCR
enters a mode other than
recording (i.e. recording pause,
stop mode, etc.), a LOW signal (0
V) is output. If recording is
resumed, then a HIGH signal (5
V) is output.
If in the (SET UP 3) menu, in the
BUZZER section, WARNING is
set to “Y”, a buzzer will be heard
while the VCR is in non recording
mode. The buzzer will stop if the
STOP button is pressed (the
output signal will remain LOW (0
V)).
4 Press the PAUSE/SEARCH button to save the
setting.
5V (H)
0V (L)
(Output impedance: 5.7 k)
FIELD: 16.7 msec.
FRAME: 5 msec.
NU4Q/U3 (SRC-850 GB) Mon. Aug., 23/1999
English
27