Seagate 77767496 TV Cables User Manual


 
306 Fibre Channel Interface Manual, Rev. D
- accept the parameter list, and if no errors are detected in the parameter list, return Good status. The requested
diagnostic operation and the preparation of the parameter data to be returned are performed upon receipt of a
Receive Diagnostic Results command.
1 Directs the device server to complete the target’s Default Self-Test. If the test passes successfully, the command is
terminated with Good status; otherwise, the command is terminated with Check Condition status and the sense key
is set to Hardware Error.
Self-Test Code
1 The Self-Test Code field shall contain 000b.
0 The contents of the Self-Test Code field are as specified below:
Unit OFL (Logical Unit Off Line)
0 Disables write operations on user medium or operations that affect user visible medium positioning. This bit is not
interpreted by the disc drive.
Value Function name Description
000b N/A This value is used when the Self Test bit is 1 or if one of the other supported diagnos-
tic pages is being transferred.
001b Background Short
Self-Test
The device server starts its short self-test (see Section 13.2.2) in the background
mode (see Section 13.2.3.2). The Parameter List Length field contains 0.
010b Background
Extended Self-Test
The device server starts its extended self-test (see Section 13.2.2) in the background
mode (see Section 13.2.3.2). The Parameter List Length field contains 0.
011b Reserved.
100b Abort Background
Self-Test
The device server aborts the current self-test running in background mode. The
Parameter List Length field contains 0. This value is only valid if a previous Send
Diagnostic command specified a background self-test function and that self-test has
not completed. If either of these conditions is not met, the device server returns a
Check Condition status with a Sense Key of Illegal Request and an Additional Sense
Code of Invalid Field in CDB.
101b Foreground Short
Self-Test
Not supported.
110b Foreground Extended
Self-Test
Not supported.
111b Reserved Reserved.
205
205