Transition Networks DVP 5140K Cable Box User Manual


 
4. Is Management Connection Good?
If the Management READY LED is OFF:
Ensure that the Management Module is seated firmly in the
Multichannel Media Converter.
Ensure that the Management Module is configured properly
(See Section 3 INSTALLATION).
If the configuration menu isn’t readable or doesn’t appear at all:
Ensure that the serial cable is good.
Ensure that the terminal settings are good.
If there is no SNMP response from the manager:
Check the IP address on the configuration menu.
Try to use the "ping" command.
If there is no “ping”
Check the Ethernet cable.
Check the LNK LED.
If there are no traps:
Check the SNMP manager IP address in the trap destination
on the configuration menu.
If the Multichannel Media Converter doesn’t appear in the MIB
browser:
Ensure that the Multichannel Media Converter MIB file is
copied to the proper location in the remote Network
Management Station.
Ensure that the MIBs are compiled with the new file.
4. Is the Management Module connected to an active
10BASE-T Ethernet port?
Ensure that the Management LNK LED indicator is
illuminated, indicating a good link.
Ensure that the Management REC LED indicator is blinking,
indicating that the Management Module is receiving data.
Failure may indicate that Multichannel Media Converter
Management Module connection to the network has failed.
Verify the integrity of the 10BASE-T hub/switch port to
which the Multichannel Media Converter is attached.
Verify the integrity of the 10BASE-T twisted-pair Ethernet
cable that leads from the hub/switch to the Multichannel
Media Converter.
Contact TRANSITION Networks Technical Support.