12.4.6. Password
The Remote Controller's operation level can be set using passwords. The table below shows the available and
unavailable functions of each operation level. Please set the appropriate operation level referring to this table.
High Low
Menu Setting
Archive
Recording/Playback
Priority Recording
Triplex
Camera Operation
Live Screen Operation
Alarm Reset
Buzzer Reset
Operation Level 1 Operation Level 2 Operation Level 3
Full-Lock
Operation Level 1
All functions available, including setting changes and archiving. Entering the corresponding password
gives access to Operation Level 1 from any other operation level.
Operation Level 2
Live and recorded images can be monitored, however setting changes and archiving cannot be
operated. Entering a password for operation level 2 allows login to operation level 2.
Operation Level 3
Only recorded images can be monitored. The Priority Recording key can be used if settings are
performed(*
1
). Entering a password for operation level 3 allows login to operation level 3.
Full-Lock
No operation possible. If Operation Level 3 is valid (Password #3 has been set), the system
automatically switches to “Full-Lock” mode when the user logs out of Operation Level 3 or when the
log-out interval elapses.
Log-Out Time Can be set to 1, 5, 10, 30 or 60 minutes or OFF.
If no operations areperformed for a pre-set period of time after log-in, the systemautomatically logs
out, moving to the lowest set operation level.
[Example] When Operation Levels 1 and 2 are valid (Passwords 1 and 2 have been set),
the operation level after log-out is Level 3.
Priority recording
operator Level 3
Selecting ON permits the Priority Recording key to be used even when Operation Level 3 is valid.
If OFF is selected, the Priority Recording key cannot be used when Operation Level 3 is valid.
Regardless of this ON/OFF setting, the Priority Recording key can always be used at Operation
Levels 1 and 2, and cannot be used when in Full-Lock mode.
(*
1
) Whether or not to make the Priority Recording key usable at Operation Level 3 can be set in the “Priority Recording
Operation Level 3” settings.
(*
2
) The Camera menu cannot be displayed.
(Factory-preset to OFF.)
(*