Front Panel Message Possible Cause
No ID Tag found No carrier ID tag found on newly-acquired carrier; if carrier ID
tag match is required, cannot access this Transport
No LAN detected No Ethernet network detected at LAN port
No Modem Dial Tone No dial tone on phone line
No PAT No PAT (Program Association Table) found in initial Verify
Transport [if a warning, while occurring & carrier/ASI still locked]
No PMT No PMT (Program Map Table) found for Program listed in PAT
No PPP Connection PPP connection couldn't be established.
No Signal No carrier lock and no RF power detected at RF input
No valid software At unit boot-up, boot loader detects no valid application present to
load and run; unit will be inoperative & needs to be returned for
service
PAT Disappeared PAT lost after first being verified
Playlist Doesn't Exist Playlist to play doesn't exist
PMT Disappeared PMT disappears or becomes corrupt
Program not found Requested program number not listed in current PAT
Recovery Auto-Recovery in progress
Reverted to B-up app User-requested application failed self-test and Unit reverted to
Backup application [until next commanded app switch]
Sec Micro no resp Secure micro cannot be accessed at bootup in order to verify unit
serial number
Using backup setting Current settings derived from successful Auto- Recovery [until
local or network user setting command]
Unit overheating Unit temperature sensor detects very high internal temperature;
operator needs to check that ventilation fans have not failed, vents
are clear, and ambient temperature is not exceeded