4 — MAINTENANCE
Troubleshooting Aids
See Table 4-4 for interpreting LED indicators located on the main controller board
shown in Figure 4-14. Hydraulic and PC logic diagrams are shown in Figures 4-15 and
4-16. An electrical wiring diagram is shown in Figure 4-17.
EASI-24V
EASI-GND
2 AMP FUSE
EASI-TXD
EASI-RXD
RS232-RXD
RS232-TXD
RS232-GND
CANH
CANL
CAN P5V
CAN GND
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
MAST SWITCH
UPPER CONTROLS
LOWER DOWN
LOWER UP
TILT SENSOR
UNDERCAGE SAFETY
DIN1
DIN2
MAST DOWN
UP CTRL SELECTED
LOWERING
RAISING
MACHINE LEVEL
UNDERCAGE OK
DIN1 ON
DIN2 ON
SPARE +5V
AGND
AIN1
STEERING +5V
STEERING GND
STEERING IN
DIAG
LEDS
JTAG DB-9
BUZZER
HOUR METER
HORN
BUZZER ONBUZZER
ON
HRMTR ON
HORN ON
PWR
PWR
PWR
10 AMP FUSE
UP ON
DOWN ON
DOUT2 ON
DOUT1 ON
LEFT ON
RIGHT ON
PUMP ON
PWR
PWR
PWR
PWR
PWR
PWR
PUMP
RIGHT
LEFT
DOUT1
DOUT2
DOWN
UP
PWR GND
PWR POS
Figure 4-14. Main Controller Board