A SERVICE OF

logo

Epson
ESUP
Commands Arranged by Topic
ESC
I
Format:
Master Select
ASCII code:
ESC
I
n
Decimal
:
27
33
n
Hexadecimal:
1B
21
n
Comments:
Select any valid combination of the modes in the table below.
The variable
n
is determined by adding together the values of the
desired modes from the table.
Mode
Dee
Hex
10
cpi
0 00
12
cpi
1
01
Proportional
2
02
Condensed
4
04
Emphasized
8
08
Double-strike
16 10
Double-wide 32 20
Italic 64 40
Underline
126
80
This command applies to both draft and
NLQ.
10
cpi
cannot be
combined with
12
cpi,
and proportional cannot be condensed. If
both proportional and condensed are selected, proportional
overrides condensed. If both emphasized and condensed are
selected, emphasized is ignored. Double-strike is ignored in
NLQ.
For more information on selecting
typestyles
with Master Select, see
Chapter
4.
9-24
command summary