78-8135-4385-3-A 7
4.4 Insert the connector into the hot melt connector
holder.
4.5 Place the load adapter, with slot aligned with handle,
into an available port in the oven.
IMPORTANT: Do not place connector in a hot load
adapter. This may cause adhesive to flow to the
outside of the ferrule. Load adapter should be at room
temperature when connector is inserted.
4.6 The 3M
™
LC Hot Melt Connector should be in the
oven for at least 75 seconds. The connector should not
be in the oven longer than 5 minutes.
4.7 Place the heat shrink fixture in an available port in the
oven.
Note: This step is only necessary for use with the
1.6–2.0 mm jacketed LC hot melt connector.