Divar | Installation Manual | Hardware setup EN | 4-5
Ethernet connection
The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC
or to a network. The Ethernet is also used to connect to an ATM/POS bridge
unit. To connect directly to a network hub, use a straight-through network cable.
To connect directly to a PC, use the supplied cross-over network cable. Consult
with your local IT personnel for the specific type of cable needed. The cable
length from node to node is limited to 100 feet (30.5 meters) maximum length
and 6 feet (1.8 meters) minimum length.
Network configuration
The Divar is delivered with the DHCP function switched on, so IP addresses are
assigned automatically if the network server uses DHCP. (Refer to the
System
settings/Connectivity/Network setup menu.)
Specifications
Connection: 10/100 BaseT, IEEE 802.3
Differential signal voltage: ± 2.8V max, inputs have transient overvoltage
protection.
Port details: IEEE 802.3/802.3u - 100Base-TX/10Base-T physical
layer.
Auto Negotiation: 10/100, Full / Half Duplex
Cable length: 100 Meters: 100 Ohm unshielded twisted pair cable,
category 3/4/5.
100 Meters: 150 Ohm shielded twisted pair cable.
Impedance: In-built compensation for impedance matching.
Indicators: ACT, 10, 100
LAN - RJ-45 Ethernet socket
Signal Name: Pin no. Description
LAN_TX+ 1 Ethernet transmit line plus
LAN_TX- 2 Ethernet transmit line minus
LAN_RX+ 3 Ethernet Receive line plus
N/C 4 No Connection
N/C 5 No Connection
LAN_RX- 6 Ethernet receive line minus
N/C 7 No Connection
N/C 8 No Connection
81