35
© 2006 directed electronics
ccoonnttrrooll mmoodduullee pprrooggrraammmmiinngg
Depending on the vehicle, use the following data with the
instructions to program your system. These wire loops are found
at the side of the control module.
DDoooorr LLoocckk PPuullssee DDuurraattiioonn ((WWHHIITTEE))
- Some European vehicles,
such as Mercedes-Benz and Audi, require longer lock and unlock
pulses to operate the vacuum pump. Programming the system to
provide 3.5 second pulses will accommodate door lock interface
in these vehicles. The default setting is 0.8 second door lock
pulses. See Mercedes-Benz and Audi - 1985 and Newer (Type E
Door Locks section) diagram.
Uncut – 0.8 seconds
Cut – 3.5 seconds
DDoouubbllee PPuullssee UUnnlloocckk SSiinnggllee PPuullssee//DDoouubbllee PPuullssee ((GGRREEEENN))
-
Some vehicles require two pulses on a single wire to unlock the
doors. When the double pulse unlock feature is turned on, the
H1/12 BLUE/BLACK wire will supply two pulses instead of a
single pulse. This makes it possible to directly interface with
double pulse vehicles without any extra parts.
Uncut – single pulse
Cut – double pulse
G21994_04-06.qxd 12/11/06 3:36 PM Page 35