D-Link DGS-1210-24 TV Receiver User Manual


 
Configuration D-Link Web Smart Switch User Manual
8
8
7
7
Figure 4.106SNMP > RMON > RMON Alarm Settings
The configuration contains the following fields:
Index (1 ~ 65535): Indicates the RMON alarm entry number.
Variable: Specify the selected MIB variable value.
Rising Threshold (0 ~ 2^31-1): Displays the rising counter value that triggers the rising threshold alarm.
Rising Event Index (1 ~ 65535): Displays the event that triggers the specific alarm. The possible field
values are user defined RMON events.
Owner: Displays the device or user that defined the alarm.
Interval (1 ~ 2^31-1): Defines the alarm interval time in seconds.
Sample type: Defines the sampling method for the selected variable and comparing the value against the
thresholds. The possible field values are:
Delta value Subtracts the last sampled value from the current value. The difference in the values
is compared to the threshold.
Absolute value Compares the values directly with the thresholds at the end of the sampling
interval.
Falling Threshold (0 ~ 2^31-1): Displays the falling counter value that triggers the falling threshold alarm.
Falling Event Index (1 ~ 65535): Displays the event that triggers the specific alarm. The possible field
values are user defined RMON events.
Click Add to create a new entry. Click Delete to remove the corresponding entry.
The RMON Event page contains fields for defining, modifying and viewing RMON events statistics.
SNMP > RMON > RMON Event
Figure 4.107SNMP > RMON > RMON Event Settings
The RMON Events Page contains the following fields:
Index (1~ 65535): Indicates the RMON event entry number.
Description: Specifies the user-defined event description.
Type: Specifies the event type. The possible values are:
None Indicates that no event occurred.
Log Indicates that the event is a log entry.
SNMP Trap Indicates that the event is a trap.