EverFocus EMV200 DVR User Manual


 
33
Network Loss:
Figure 4-17 Alarm – Event – Network Loss
Alarm Output: This will transmit a signal through the alarm output relay. It can be set to either “NONE” (not active)
or “1 (active).
Output Type: Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “Enter” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration: The amount of time the buzzer sounds when DVR stops recording. Duration selectable from 1
to 150 seconds.
NOTE: This function only checks the physical connection (link) to the network. Any network behavior that
blocks data connectivity (blocked ports, IP addressing errors, etc.) is not detected by this function.
Click button to return to the previous level of menu.