Network Port Specific Options
Option Function Comment
0 and 10 Network port link
speed
z Option 0 allows the speed of the RJ45 network port to be
set manually.
z Option 10 reports the speed of the SFP port; this is xed at
1Gbs
1 and 11 Set STATIC or DHCP Entering 1 (11) will toggle this option. When DHCP is selected
items 2 (12) through 5 (15) are not accessible.
NOTE: It is necessary to assign a known IP
address for the controller. This address
must be entered manually into each
VN-Matrix 300 unit. Therefore it is
not always practical to use DHCP. It is
recommended to use a static IP address
scheme.
2 and 12 Set the local address of
the Network port
z Network port 1 is assigned to the RJ45 connector.
z Network port 2 is assigned the SFP connector.
z Standard ETHERNET IP addressing rules apply.
Do not use any leading zeroes in the IP address, for example
172.28.12.100 is valid, 172.028.012.100 is not valid.
3 and 13 Set the appropriate
subnet mask for the
network.
z Standard ETHERNET subnet rules apply.
z Do not use leading zeroes in the subnet mask
z such as 255.255.10.0 is valid, 255.255.010.0 is not valid.
4 and 14 Set the IP address of
the default gateway.
z Required for VN-Matrix 300 systems that include multiple
subnets.
The default gateway must be on the same subnet as the as
the port to which it is assigned.
z Only one default route is supported. Once a value is set
on either option, the other option is no longer available.
To clear a gateway address, select the option (4 or 14) and
enter return with no value set.
z Standard ETHERNET IP addressing rules apply.
Do not use any leading zeroes in the IP address for example
172.28.12.100 is valid, 172.028.012.100 is not valid.
5 and 15 Set the broadcast
address.
Not required.
6 and 16 Set the value of
the maximum
transmission unit, that
is, the number of bytes
(payload) in a frame.
z This value will affect the performance of the system. A large
value can cause packets to be fragmented (split) whilst
a small value may not make efficient use of the network
capacity.
z For ETHERNET this value is normally set to 1500. In certain
circumstance this value may need to be changed to better
match the network that is in use.
Unit Specific Options
7 Set the IP address of
the controller.
z Remember that one (and only one) VN-Matrix 300 must be
configured as a controller.
z The controller IP address must be set to the IP Address
(option 2 and 12) of either Network port on the unit
designated as the controller. This is port over which control
data is sent.